wiDom Energy Driven Switch versión C View larger

wiDom Energy Driven Switch versión C

WPMC

New

Out of stock

74,99 €

Technical characteristics

Technology Z-Wave Plus
Characteristic Consumption Measurement

Extended Z-Wave info

Name: Energy Driven Switch Version C
Manufacturer:Widom
Identifier:WPM1.04C
Z-Wave Certification Number:ZC10-15030011
Hardware Plattform:ZM5202
FLiRS:NO
Role Type:Always On Slave
Short Description:The smallest device in its category worldwide, specifically intended for use both as a Relay Switch with integrated power meter, and as an Energy Meter either at the point of entry of your electrical system, or on a section of the latter. In addition to Power measurements, the device also provides data for Energy, Voltage, Current and Power factor.
Description:The smallest device in its category worldwide, and the only device specifically intended for use both as a Relay Switch with integrated power meter, and as an Energy Meter either at the point of entry of your electrical system, or on a section of the latter. Available in two versions, version S featuring an internal shunt resistor, and version C featuring an external current transformer, it is capable of measuring loads exceeding 10 KW. In addition to Power measurements, the device also provides data for Energy, Voltage, Current and Power factor. The only device suited for use with all types of Z-Wave controller, and capable of implementing an active energy-saving management policy defined by the user according to his energy consumption, or to the amount of energy produced by his solar power system. It automatically connects and disconnects a specific load if the threshold limit is exceeded, or “supplies” the required power, momentarily excluding non-priority loads. Main Feature: • Active Energy-saving Management • Control and monitoring of usage • Control and monitoring of production and net metering • Monitoring of all network parameters (Power, Energy, Voltage, Current, Power Factor) • Provides bidirectional measurements for Power and Energy (produced/consumed). • Management and prevention of electrical faults • Intelligent Opening/Closing of the Relay • Control of heavy loads • Software Update • Extremely low energy usage

Manual download HERE.

Group
Max Nodes
Description
1
8
Z-Wave Plus Lifeline: Devices to receive notifications on: status changes; energy and power levels; device local reset
2
8
Up Power Level Group: Devices controlled by the Up Power event
3
8
Down Power Level Group: Devices controlled by the Down Power event
Number
Size (Bytes)
Default Value
Name
Description
1
1
1
Device Status
Controlling the relay by means of a single click on the external switch or on the integrated button.
20
1
0
Device status upon receipt of a Basic Set command
The final status achieved by the device when it receives a Basic Set command through the Z-Wave network.
30
2
4500
Overcurrent level
Sets the current level above which the time spent above that level is measured.
31
2
10
Overcurrent time
Sets the time beyond which, in the case of overcurrent at a level higher than that established in parameter 30, an OverCurrent event occurs.
32
1
0
Next State
Defines the next state of the device if an overcurrent event has occurred.
33
4
1
Meter Reset
Provides total operating time from last meter reset. When set to 0 it resets the cumulated values of energy and total operating time.
34
1
1
Energy flow
Determines whether energy events are related to energy consumed or energy produced.
35
2
1250
UP Power Level
Sets the level of instantaneous power in Watts beyond which time of permanence above this level is calculated.
36
2
0
UP Power Time
Sets the time in seconds beyond which, if instantaneous power remains at levels exceeding threshold defined by parameter 35, a UP Power event occurs.
38
1
0
UP Power Associated
Defines the status of associated devices in the presence of a UP Power event.
39
2
0
DOWN Power Level
Sets the level of instantaneous power beyond which the time of permanence below this level is calculated.
40
2
10
DOWN Power Time
Sets the time beyond which, if instantaneous power remains at levels below threshold defined by parameter 39, a DOWN Power event occurs.
41
1
0
DOWN Power State
Defines the next state of the device in the case of a DOWN Power event occurring.
42
1
0
DOWN Power Associated
Defines the status of associated devices in the presence of a DOWN Power event.
43
4
2000000
Energy Level
Sets the energy level that once exceeded an Energy Limit event occurs.
44
1
0
Energy Limit State
Defines the next state of the device in the case of an Energy Limit event occurring.
45
1
10
Variation Instantaneous Power
Defines the percentage variation of instantaneous power determining the sending of the report.
46
1
10
Report Time Frequency
Defines the maximum time in minutes since the previous report beyond which an Instantaneous Power Report will still be sent.
48
2
2300
Nominal Voltage
Defines the nominal voltage value in tenths of volts. Together with parameter No. 49 this is used by the automatic notification system to send reports on variations of voltage.
49
1
10
Fall in maximum voltage
Defines, as a percentage, the nominal value for permitted fall in maximum voltage.
50
1
30
Electric parameters subjected to automatic notification
Defines which electric parameters, other than power, will be subjected to automatic notification. The value to be set for this parameter must be calculated as the sum of values associated to the individual electric parameter.
60
1
3
Start-up status
Defines the status of the device following a restart.
61
1
4
Configuration reset
Defines which parameters should be reset to default values.
62
1
4
Type of external switch
Defines the type of external switch connected to the device.
63
1
1
Load control
Defines the load control mode.
Basic
COMMAND_CLASS_BASIC
Device Reset Locally
COMMAND_CLASS_DEVICE_RESET_LOCALLY
Inclusion
1. Put your system controller into inclusion mode by following the instructions provided by your controller manufacturer.
2. Press the push button (B) located on the top of the device once.""
Exclusion
1. Put your system controller into exclusion mode by following the instructions provided by your controller manufacturer.
2. Press the push button (B) located on the top of the device three time.""
Factory Reset
Press the push button (B) located on the top of the device six consecutive times within one minute from system start-up. Please use this procedure only in the event that the primary controller is missing or otherwise inoperable.
Additional Special Features
Before invoke the firmware update from the controller press the push button (B) located on the top of the device four consecutive times.

 