Viewed products





Confianza Online


domoticalia.es/es/ Reviews with ekomi.es

DOORBIRD Estación de videoportero IP D203

PST02-1C

New

Z-Wave multisensor for sensing the opening of doors or windows, brightness (lumens) and ambient temperature

More details

In Stock

38,99 €

Technical characteristics

Technology Z-Wave Plus

More info

With Philio's 3-in-1 PST02-1C sensor you can not only monitor the status of your doors and windows, as the device is equipped with 3 different sensors in total:

Door and window sensor
Temperature sensor
Light sensor
The sensor consists of two parts: a detector and a magnet. The magnet must be mounted on the opening part of the door / window and the detector on the fixed frame. Opening the door / window will eliminate the magnetic field, activate the detector and generate an alarm condition, (if the system is armed).

The sensor can also be used for automatic light control, one possible scene is to get the illumination lux level from the built-in light sensors and send a signal to the Z-Wave control center to turn on the light once the door open when the room is dark. Every time when the door / window sensor triggers a state change, it will also send the temperature and brightness value.

Features:

Contact sensor monitors door and window status (open / closed)
Measure and report additional temperature and brightness values
Tamper protection
Can be mounted on any flat surface in a vertical or horizontal position
Firmware update "Over The Air" (OTA)
Power supply: Battery (1x CR123A)
Wireless technology: Z-Wave Plus
Dimensions: 28 x 95 x 35 mm

Extended Z-Wave info

Name: Slim Multisensor
Manufacturer:Philio
Identifier:PST02-1C
Z-Wave Certification Number:ZC10-14080018
Hardware Plattform:SD3502
FLiRS:NO
Role Type:Reporting Sleeping Slave
Short Description:Slim Multisensor 3 in 1 (Door/Window, Temperature and Illumination)
Description:The slim multisensor PST02 has door/window, temperature and illumination, 3 sensors function in one,based on Z-Wave technology.

Manual download HERE.

Group
Max Nodes
Description
1
8
Z-Wave Plus Lifeline
2
8
Using the "Basic Set" for lighting control.
Number
Size (Bytes)
Default Value
Name
Description
10
1
12
Auto Report Battery Time
The interval time for auto report the battery level. 0 means turn off auto report battery. The default value is 12. The tick time can setting by the configuration No.20.
11
1
12
Auto Report Door/Window State Time
The interval time for auto report the door/window state. 0 means turn off auto report door/window state. The default value is 12. The tick time can setting by the configuration No.20.
12
1
12
Auto Report Illumination Time
The interval time for auto report the illumination. 0 means turn off auto report illumination. The default value is 12. The tick time can setting by the configuration No.20.
13
1
12
Auto Report Temperature Time
The interval time for auto report the temperature. 0 means turn off auto report temperature. The default value is 12. The tick time can setting by the configuration No.20.
2
1
255
Basic Set Level
Setting the BASIC command value to turn on the light. The 0xFF(-1) means turn on the light. For dimmer equipment 1 to 100 means the light strength. 0 means turn off the light.
20
1
30
Auto Report Tick Interval
The interval time for auto report each tick. Setting this configuration will effect configuration No.10, No.11, No.12 and No.13. Caution: Setting to 0 means turn off all auto report function.
21
1
1
Temperature Differential Report
The temperature differential to report. 0 means turn off this function. The unit is Fahrenheit. Enable this function the device will detect every minutes. And when the temperature is over 140 degree Fahrenheit, it will continue report. Enable this functionality will cause some issue please see the detail in the “Temperature Report” section.
22
1
0
Illumination Differential Report
The illumination differential to report. 0 means turn off this function. The unit is percentage. Enable this function the device will detect every minutes. Enable this functionality will cause some issue please see the detail in the “Illumination Report” section.
4
1
99
Light Threshold
Setting the illumination threshold to turn on the light. When the event triggered and the environment illumination lower then the threshold, the device will turn on the light. 0 means turn off illumination detected function. And never turn on the light. 1 means darkest. 99 means brightest. 100 means turn off illumination detected function. And always turn on the light. Notice: In none test mode, only the value in 1 to 99 will enable the illumination detected function and update the illumination value.
5
1
0
Operation Mode
Operation mode. Using bit to control. Bit0: Reserve. Bit1: 1 means test mode, 0 means normal mode. Notice: This bit only effect by the DIP Switch setting to “customer mode”, otherwise it decides by DIP Switch setting to Test or Normal Mode. Bit2: Disable the door/window function. (1:Disable, 0:Enable) Bit3: Setting the temperature scale. 0: Fahrenheit, 1:Celsius Bit4: Disable the illumination report after event triggered. (1:Disable, 0:Enable) Bit5: Disable the temperature report after event triggered. (1:Disable, 0:Enable) Bit6: Reserve. Bit7: Disable the back key release into test mode. (1:Disable, 0:Enable) Notice: The reserve bit is allowed any value, but no effect.
6
1
4
Mult-Sensor Function Switch
Multisensor function switch. Using bit to control. Bit0: Disable magnetic integrate illumination to turn ON the lighting nodes in the association group 2. (1:Disable, 0:Enable) Bit1: Reserve. Bit2: Reserve. Bit3: Reserve. Bit4: Disable delay 5 seconds to turn off the light, when door/window closed. (1:Disable, 0:Enable) Bit5: Disable auto turn off the light, after door/window opened to turn on the light. (1:Disable, 0:Enable) Notice: If bit2 is zero, this setting is useless. Notice: If the configuration No.9 is zero, this setting is useless. Bit6: Reserve. Bit7: Reserve. Notice: The reserve bit is allowed any value, but no effect.
7
1
4
Customer Function
Customer function switch, using bit control. Bit0: Reserve. Bit1: Reserve. Bit2: Reserve. Bit3: Disable send out BASIC OFF after door closed. (1:Disable, 0:Enable) Bit4: Notification Type, 0: Using Notification Report. 1: Using Sensor Binary Report. Bit5: Disable Multi CC in auto report. (1:Disable, 0:Enable) Bit6: Disable to report battery state when the device triggered. (1:Disable, 0:Enable) Bit7: Reserve. Notice: The reserve bit is allowed any value, but no effect.
9
1
4
Turn Off Light Time
After turn on the lighting, setting the delay time to turn off the lighting when the PIR motion is not detected. 8 seconds per tick, default tick is 4 (32 seconds). 0 means never send turn off light command.
Basic
COMMAND_CLASS_BASIC
Inclusion
There are two tamper keys in the device, one is in the back side, another is in the front side. Both of them can add, remove, reset or association from Z-Wave network.
To add into a Z-Wave network:
1. Have Z-Wave Controller entered inclusion mode.
2. Pressing tamper key three times within 1.5 seconds to enter the inclusion mode.
3. After add successful, the device will wake to receive the setting command from Z-Wave Controller about 20 seconds.
Exclusion
There are two tamper keys in the device, one is in the back side, another is in the front side. Both of them can add, remove, reset or association from Z-Wave network.
To remove the device from a Z-Wave network:
1. Have Z-Wave Controller entered exclusion mode.
2. Pressing tamper key three times within 1.5 seconds to enter the exclusion mode.
Node ID has been excluded.
Device Wake-Up
There are two tamper keys in the device, one is in the back side, another is in the front side. Both of them can add, remove, reset or association from Z-Wave network.
Press any key once, the device will awake 10 seconds.
Factory Reset
There are two tamper keys in the device, one is in the back side, another is in the front side. Both of them can add, remove, reset or association from Z-Wave network.
To reset the device:
Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable.
1. Pressing tamper key four times within 1.5 seconds and do not release the tamper key in the 4th pressed, and the LED will light ON.
2. After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second. Otherwise, the LED will flash once.
3. IDs are excluded and all settings will reset to factory default.

 

Reviews

Write a review

DOORBIRD Estación de videoportero IP D203

DOORBIRD Estación de videoportero IP D203

Z-Wave multisensor for sensing the opening of doors or windows, brightness (lumens) and ambient temperature

8 other products in the same category: