Name: Smart Smoke Sensor
Manufacturer:HEIMAN
Identifier:HS3SA-Z
Z-Wave Certification Number:ZC10-19076680
Hardware Plattform:ZM5202
FLiRS:NO
Role Type:Reporting Sleeping Slave
Short Description:The smart smoke alarm is a battery operated, photoelectric alarm. This unit is designed to alert you and your family to the dangers of smoke and fire.
Description:The smart smoke alarm is a battery operated, photoelectric alarm. This unit is designed to alert you and your family to the dangers of smoke and fire. When detected smoke reaches the set threshold value, the smoke alarm will issue visible and audible alarm signals and send alarm notification to user APP.
Group
Max Nodes
Description
1
5
Association group 1: Lifeline association group
‐ Maximum supported node is 5.
Include command classes: Battery report, Notification report, and Device Reset Locally
notification,
2
5
Association group 2: Root Device group(Basic set)
‐ Maximum supported node is 5.
The Sensor sends a Basic Set command to directly trigger devices (like a light, switch, etc.) in
response to events. The value of the Basic Set command (e.g. Siren trigger) is configured using
smoke or no smoke
Number
Size (Bytes)
Default Value
Name
Description
Basic V2
COMMAND_CLASS_BASIC_V2
Association Group Info
COMMAND_CLASS_ASSOCIATION_GRP_INFO
Association V2
COMMAND_CLASS_ASSOCIATION_V2
Battery
COMMAND_CLASS_BATTERY
Device Reset Locally
COMMAND_CLASS_DEVICE_RESET_LOCALLY
Manufacturer Specific V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
Multi-Channel Association V3
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
Notification V8
COMMAND_CLASS_NOTIFICATION_V8
Powerlevel
COMMAND_CLASS_POWERLEVEL
Security S2
COMMAND_CLASS_SECURITY_2
Supervision
COMMAND_CLASS_SUPERVISION
Transport Service V2
COMMAND_CLASS_TRANSPORT_SERVICE_V2
Version V3
COMMAND_CLASS_VERSION_V3
Wake Up V2
COMMAND_CLASS_WAKE_UP_V2
Z-Wave Plus Info V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
Inclusion
Device ADD for Inclusion
- Click [Add] icon in Z-Wave Controller .
- Press the Net_Button 3 times within 1.5s, Green LED is Blinking 3 times within 1 second.
- If Inclusion Process is successful, Green led will turn off.
Factory Reset
Device Factory Reset
--Long press Net_Button at least 10 seconds in the product.
- Device Reset Locally notification is Transmitted.
. Please use this procedure only when the network primary controller is missing or otherwise inoperable.
Exclusion
Device Remove for Exclusion
- Click [Remove] icon in Z-Wave Controller
- Press the Net_Button 3 times within 1.5s
- If Exclusion Process is successful, Green led is Blinking 6 times, then turn off.
S2 Unauthenticated
S2_UNAUTHENTICATED
Battery Type
Enter the type (e.g. AA, CR2032, AAA) of the battery/batteries that the product uses.
Color
If the product is only available in one color, pick the color from the list.
Supported Notification Types
Select the Notification Types that the product handles (controllers), or sends (slaves).
Battery Quantity
Enter the number of batteries of the designated type that the product uses.