FIBARO Wall Plug GEN 5 Plug Z-Wave (on / off) with consumption meter

FGWPF-102-5

New

The Fibaro wall plug is an extremely compact Z-Wave Plus smart plug module, which can control the lighting or other equipment connected to your outlet. It is the smallest controlled plug by Z-Wave on the market.

More details

Out of stock

73,81 €

Technical characteristics

Technology Z-Wave Plus
Characteristic Consumption Measurement

More info

The Fibaro controlled plug is an intelligent and extremely compact module, which allows you to control lighting and other devices through Z-Wave commands. It is designed to work with any type of electrical load of up to 2500W of maximum power.

This module also has the function of measuring the energy consumption. Therefore, the instantaneous consumption values and the total consumption are sent to the Z-Wave Control Unit. A visual indicator also allows to know at a glance the consumption: a luminous ring type LED green indicates a low consumption of energy, while a luminous ring type red LED, indicates a very high consumption.

This module also offers a unique feature: the ability to test the coverage of the Z-Wave network. Just press a few seconds of the module key, the violet light LED informs you that the system is in test mode, allowing you to see the current coverage by the color shown.

A Z-Wave Control Unit (controller) is necessary to integrate this module into the network. Each Z-Wave module acts as a wireless repeater with other modules to ensure total coverage in your home.

CHARACTERISTICS:

  • It allows to control a lamp or an electrical device.
  • Integrates directly into an outlet (plug type schuko)
  • The most compact on the market, which allows the use of adjacent plugs
  • ON / OFF control of lamps or appliances
  • Measurement of the power consumption of the connected load
  • Warning in case of overload (> 2500W)
  • Alert if the temperature is> 55 ° C
  • Load control locally through the built-in button
  • Indicates real-time consumption thanks to its light ring
  • Unique feature: Z-Wave network coverage test
  • Protection of manipulated by children and night light function
  • Upgradeable via radio ZWave with Fibaro Home Center 2
  • Ease of use and installation

SPECIFICATIONS:

  • Module type: Z-Wave / Z-Wave Plus receiver
  • Power supply: 110-230 V AC ± 10% 50 / 60Hz
  • Maximum power: 2.5 kW
  • Consumption: 0.8 W
  • Frequency: 868.42 MHz
  • Transmission distance: in open field 50 meters, 30 meters in construction
  • Dimensions: 43 x 65 mm (diameter x height)
  • Operating temperature: 0º - 40 ° C
  • Temperature limit: 105 ° C
  • Standards: EN 55015 and EN 60669-2-1
Z-Wave Plus - Fibaro ZW5 Fibaro Wall Plug ZW5

Extended Z-Wave info

Name: FIBARO Wall Plug E/F
Manufacturer:FIBARO
Identifier:FGWPE/F-102
Z-Wave Certification Number:ZC10-18025991
Hardware Plattform:ZM5202
FLiRS:NO
Role Type:Always On Slave
Short Description:FIBARO Wall Plug is a universal, Z-Wave Plus compatible, remotely controlled outlet adapter designed to control electrical devices with up to 2500W load.
Description:FIBARO Wall Plug is a universal, Z-Wave Plus compatible, remotely controlled outlet adapter. This device may be applied wherever you want to control electrical devices with up to 2500W load. The Wall Plug is equipped with a power and energy metering function. It uses a LED ring to visualize the current load with colour changing illumination and operating mode. This is the smallest and most attractive device of this type available in the world. The Wall Plug may be operated using the B-button located on its casing or via any Z-Wave compatible controller. Main features: • Compatible with any Z-Wave or Z-Wave Plus Controller. • Supports protected mode (Z-Wave network security mode) with AES-128 encryption. • Extremely easy installation - simply plug the device into the mains socket. • Works as a Z-Wave signal repeater. • Active power and energy consumption metering. • Current value of the load and operating mode are indicated by the multi-colour LED ring.

Manual download HERE.

Group
Max Nodes
Description
1
1
“Lifeline” reports the device status and allows for assigning single device only (main controller by default).
2
10
“On/Off (button)” devices in this group will be switched on or off when relay status is changed using the B-button (done via BASIC SET command frames).
3
10
“On/Off (power)” devices in this group will be switched on or off depending on the current load (done via BASIC SET command frames).
Number
Size (Bytes)
Default Value
Name
Description
1
1
0
Always On function
Once activated, Wall Plug will keep the connected device constantly ON, will stop reacting to alarm frames or pushing the B-button. “Always On” function turns the Wall Plug into a power and energy meter. Connected device will not be turned off upon receiving an alarm frame from another Z-Wave device (parameter 31 will be ignored). In “Always on” mode, connected device may be turned off only after user defined power has been exceeded (parameter 3). In such a case, connected device can be turned on again by pushing the B-button or sending a control frame. By default, overload protection is inactive.
10
1
80
High priority power report
This parameter determines the minimum percentage change in active power that will result in sending power report to the main controller with the highest priority in the Z-Wave network. By default, the Wall Plug immediately sends the power report if the power load changes by 80%. NOTE In extreme cases, reports may be sent every second if rapid and significant power load changes occur. Frequent reporting may overload the Z-Wave network so these parameter’s settings should reflect significant changes in power load only.
11
1
15
Standard power report
This parameter determines the minimum percentage change in active power that will result in sending power report to the main controller Compared to parameter 10, the maximum number of reports sent is reduced (parameter 12) to 5 in a specified time interval. In addition, the frames are not sent in EXPLORE mode, which prevents overloading the Z-Wave network. By default changes in power load may be reported up to 5 times per 30 seconds, when power load changes by 15%.
12
2
30
Power reporting interval
This parameter defines how frequently standard power reports (parameter 11) are sent. By default the Wall Plug sends up to 5 reports each 30 seconds, provided the power load changes by 15%.
13
2
10
Energy reporting threshold
This parameter specifies the minimum change in energy consumption (in relation to the previously reported), that will result in sending a new report.
14
2
3600
Power and energy periodic reports
This parameter defines time period between reports sent when changes in power load have not been recorded or if changes are insignificant (not exceeding values of parameters 20, 21 and 23). By default reports are sent every hour.
15
1
0
Measuring energy consumed by the Wall Plug itself
This parameter determines whether energy metering should include the amount of energy consumed by the Wall Plug itself. Results are being added to energy consumed by controlled device.
2
1
1
Remember device status after a power failure
This parameter determines how the Wall Plug will react in the event of power supply failure (e.g. taking out from the electrical outlet). After the power supply is back on, the Wall Plug can be restored to previous state or remain switched off. This parameter is ignored in „Always On” mode - the device automatically turns ON after plugging it into the socket.
20
1
0
Control of „On/Off (Button)” association group (2) devices
Controlling devices with the B-Button. This parameter is inactive in “Always On” mode (parameter 1). Control as the Wall Plug: • switching the Wall Plug on – switch the devices on (parameter 24) • switching the Wall Plug off – switch the devices off (parameter 24) Control opposite to the Wall Plug: • switching the Wall Plug on – switch the devices off • switching the Wall Plug off – switch the devices on
21
2
300
DOWN value - „On/Off (Power)” association group (3)
Lower power threshold, used in parameter 23. DOWN value cannot be higher than a value specified in parameter 22.
22
2
500
UP value - „On/Off (Power)” association group (3)
Upper power threshold, used in parameter 23. UP value cannot be lower than a value specified in parameter 21.
23
1
6
The response after exceeding defined power values
This parameter defines the way that 3rd association group devices are controlled. Depends on the actual measured power (as parameters 21 and 22 settings).
24
2
255
SWITCH ON value - „On/Off” association groups
The value of BASIC SET command frame sent to the devices associated in „On/Off” association groups (2, 3). „On/Off (Button)” association group - in accordance with parameter 20. „On/Off (Power)” association group - in accordance with parameter 23. NOTE Setting parameter 24 to appropriate value will result in: 0 - turning off associated devices 1-99 - forcing level of associated devices 255 - setting associated devices to the last remembered state or turning them on
3
2
0
Overload safety switch
This function allows to turn off the controlled device in case of exceeding the defined power. Controlled device will be turned off even if “Always On” function is active (parameter 1). Controlled device can be turned back on via B-button or sending a control frame. By default this function is inactive. This functionality is not an overload safety protection nor a short circuit protection. Circuit needs additional short circuit and overload protection. CAUTION The device has a protection that will turn the load off in the case of detecting current greater than 110% of rated current. It is a safety function and it cannot be turned off. After its activation the load can be turned on back again by pressing the B-button or sending a control frame. This function is independent of overload safety switch set in the parameter no. 3.
30
1
63
Active alarms
Define Z-Wave network alarms to which the Wall Plug will respond.
31
1
0
Response to alarm frames
This parameter defines how the Wall Plug will respond to alarms (device’s status change). In case of values 1 or 2 the Wall Plug is operating normally and LED ring signals an alarm through time defined in parameter 32 or until the alarm is cancelled. In case of values 5 to 50 the Wall Plug does not report status change, power changes, ignores BASIC SET command frames. After time defined in parameter 32 or after the alarm cancellation, connected device is set to the previous state. NOTE If “Always On” function is active (parameter 1), settings of parameter 31 are ignored.
32
2
600
Alarm state duration
This parameter specifies the duration of alarm state. If a device sending an alarm frame through the Z-Wave network sets alarm duration as well, this settings are ignored.
40
2
25000
Power load for violet colour
This parameter determines active power value, which when exceeded, causes the LED ring flash violet. Function is active only when parameter 41 is set to 0 or 1.
41
1
1
LED ring colour when controlled device is on
When set to 1 or 2, LED ring colour will change depending on active power and parameter 40. Other colours are set permanently and do not depend on power consumption.
42
1
0
LED ring illumination colour when controlled device is off
This parameter defines the illumination colour after turning off. 0 - illumination turned off completely 1 - LED ring is illuminated with a colour corresponding to the last measured power, before the controlled device was turned off 3 - white, 4 - red, 5 - green, 6 - blue, 7 - yellow 8 - cyan, 9 - magenta
43
1
0
LED ring illumination colour at the Z-Wave network alarm detection
This parameter defines the illumination colour in case of Z-Wave alarm. 0 - illumination turned off completely 1 - no change in colour. LED ring colour is determined by settings of parameters 41 or 42 2 - LED ring flashes red/blue/white 3 - white, 4 - red, 5 - green, 6 - blue, 7 - yellow 8 - cyan, 9 - magenta
50
1
3
Associations in Z-Wave network security mode
This parameter defines how commands are sent in specified association groups: as secure or non-secure. Parameter is active only in Z-Wave network security mode. This parameter does not apply to 1st „Lifeline” group.
Basic
COMMAND_CLASS_BASIC
Multi-Channel V4
COMMAND_CLASS_MULTI_CHANNEL_V4
Application Status
COMMAND_CLASS_APPLICATION_STATUS
Association Group Info
COMMAND_CLASS_ASSOCIATION_GRP_INFO
Association V2
COMMAND_CLASS_ASSOCIATION_V2
Basic
COMMAND_CLASS_BASIC
Configuration
COMMAND_CLASS_CONFIGURATION
CRC16 Encapsulation
COMMAND_CLASS_CRC_16_ENCAP
Device Reset Locally
COMMAND_CLASS_DEVICE_RESET_LOCALLY
Firmware Update Meta-Data V3
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V3
Manufacturer Specific V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
Meter V2
COMMAND_CLASS_METER_V2
Multi-Channel Association V3
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
Notification V5
COMMAND_CLASS_NOTIFICATION_V5
Powerlevel
COMMAND_CLASS_POWERLEVEL
Security S0
COMMAND_CLASS_SECURITY
Sensor Multilevel V5
COMMAND_CLASS_SENSOR_MULTILEVEL_V5
Switch Binary
COMMAND_CLASS_SWITCH_BINARY
Version V2
COMMAND_CLASS_VERSION_V2
Z-Wave Plus Info V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
Exclusion
1) Plug the device into a socket nearby the main Z-Wave controller.

2) The LED ring will glow green signalling being added (removing is not necessary otherwise).

3) Set the main Z-Wave controller into remove mode (see the controller’s manual).

4) Quickly, triple click the B-button located on the casing.

5) Wait for the removing process to end.

6) Successful removing will be confirmed by the Z-Wave controller.

Inclusion
1) Plug the device into a socket nearby the main Z-Wave controller.

2) The LED ring will glow red signalling not being added (remove the device otherwise).

3) Set the main Z-Wave controller into adding mode (see the controller’s manual).

4) Quickly, triple click the B-button located on the casing.

5) Wait for the adding process to end.

6) Successful adding will be confirmed by the Z-Wave controller.

Device Wake-Up
Wakeup Description

FIBARO Wall Plug is powered with mains voltage so it is always awake.
Factory Reset
Resetting the device is not the recommended way of removing the device from the

Z-Wave network. Use reset procedure only if the primary controller is missing or

inoperable. Certain device removal can be achieved by the procedure of removing

described in “Adding/ removing the device”on page 6.



1) Make sure the device is powered.

2) Press and hold the B-button.

3) Wait for the LED ring to glow yellow (4th menu position).

4) Release the B-button.

5) Click the B-button once to confirm selection.

6) After few seconds the device will restart with factory settings, which is signalled with the red ring colour.







Supported Notification Types
Select the Notification Types that the product handles (controllers), or sends (slaves).
Sensors
Sensor types supported by the product.
Switch Load Capacity Watts
The amount of switch load energy the product is rated for in Watts
Switch Load Capacity Current
The amount of switch load energy the product is rated for in Amps
Supported Meter Type
Indicate which type of metering is supported by the device.

 

Reviews

Write a review

FIBARO Wall Plug GEN 5 Plug Z-Wave (on / off) with consumption meter

FIBARO Wall Plug GEN 5 Plug Z-Wave (on / off) with consumption meter

The Fibaro wall plug is an extremely compact Z-Wave Plus smart plug module, which can control the lighting or other equipment connected to your outlet. It is the smallest controlled plug by Z-Wave on the market.

Accessories

10 other products in the same category:

Customers who bought this product also bought: