Productos más vistos





Confianza Online


domoticalia.es/es/ Reviews with ekomi.es
Secure SRT321 Termostato de pared con pantalla LCD Z-Wave Plus GEN5 Ver más grande

Secure SRT321 Termostato de pared con pantalla LCD Z-Wave Plus GEN5

SECSRT321-5

Nuevo

El termostato de pared Secure SRT321, alimentado a pilas, permite usar una rueda grande en el dispositivo para predeterminar la temperatura deseada  en la habitación.

Más detalles

Sin Stock

89,99 €

Características técnicas

Tecnología Z-Wave Plus

Descripción

El termostato de pared Secure SRT321, de tecnología Z-Wave Plus alimentado a pilas, permite usar una rueda grande en el dispositivo para predeterminar la temperatura deseada  en la habitación. Al verificar la temperatura a alcanzar con la temperatura real medida por el dispositivo, opera sin cables un interruptor de forma inalámbrica que estaría conectado a la caldera. A su vez, mediante software de control Z-Wave puede establecer la temperatura a buscar mediante Z-Wave. Esto permite programar en el tiempo una zona a calentar. El termostato no tiene ningún tipo de temporizador interno. Se establece la configuración inalámbrica y la configuración del propio dispositivo.

 
datos técnicos
  • Tipo de dispositivo: Controlador Z-Wave
  • Baterías: 2 * AAA
  • Temperatura de Precisión: + / - 0,5 ºC
  • Rango de temperatura: 5 ... 30 ºC
  • Indice de protección: IP 30
  • Dimensiones: 86mm x 86 mm x 36,25 mm
  • Diseño Estándar: EN60730

Información Ampliada Z-Wave (Inglés)

Nombre: SRT-321 (Thermostat-HVAC)
Fabricante:Secure Controls
Identificador:MAX10U-734
Número de Certificación Z-Wave:ZC10-16015001
Plataforma Hardware:ZM5202
FLiRS:NO
Tipo de Role:Reporting Portable Controller
Descripción Corta:The SRT321 is a wireless electronic battery powered room thermostat that control central heating systems where the demand temperature can be set locally or remotely to a third party device. The SRT321 also has the capability to act as a temperature sensor.
Descripción:The thermostat includes TPI software that optimises boiler firing to minimise overshooting of temperature in a heated environment. It has been proved that TPI controllers provide considerable energy savings over standard heating controllers. By using interoperable radio solutions the user can remotely change the set point, read the temperature or receive battery reports. It makes this device an ideal partner for use with a home gateway for web enabled apps allowing you to remotely control your heating while on the move. You no longer have to worry about returning to a cold house as long as you have a phone or tablet PC handy. By combining ease of use, ease of installation and intelligent control this thermostat is suitable for use in most heating systems.

Descargue el manual desde aquí.

Grupo
Max Nodos
Descripción
1
1
Z-Wave Plus Lifeline group, SRT321 will send unsolicited Battery Level Report, Thermostat Set Point Report and unsolicited Multilevel Sensor Report to lifeline group.
2
4
Nodes controlled by Thermostat Mode SET command.
3
4
Nodes controlled by Switch Binary SET command.
4
4
Nodes to receive unsolicited Battery Level Reports or Low Battery Warnings.
5
4
Nodes to receive Thermostat Set Point Reports.
6
4
Nodes to receive unsolicited Multilevel Sensor Reports.
Número
Tamaño (Bytes)
Valor por Defecto
Nombre
Descripción
1
1
255
Enables Temperature Sensor
controls the use of the temperature sensor on the device
2
1
0
Temperature Scale
Sensor will report temperature in this scale
3
1
10
Delta Temperature
defines the temperature steps of the heating control value is 0.1˚C. (e.g. to configure 2˚C delta temperature write 2*10 = 20)
Switch Binary
COMMAND_CLASS_SWITCH_BINARY
Thermostat Mode
COMMAND_CLASS_THERMOSTAT_MODE
Exclusion
STEP 1: On the SRT321, Set DIL switch 1 on the back of the unit to 'ON' position, scroll through the function menu by rotating the dial, select ""E"" and press the dial to activate Exclusion process. Now the character ""E"" starts flashing.

STEP 2: On the 3rd party device, select Exclusion for removing device from SRT321's network.

After successful Exclusion SRT321 displayed ""EP"" other wise displayed ""EF"" (Exclusion fail).

Note: Once the character starts flashing the installer has 60 seconds to activate the 3rd party device.

After successful Exclusion set DIL switch 1 to 'OFF' position to operate SRT321 in normal operation.

If the Exclusion process has failed more than once, try moving the SRT321 to another position and repeat the Exclusion steps.
Inclusion
STEP 1: On the SRT321, set DIL switch 1 on the back of the unit to 'ON' position, scroll through the function menu by rotating the dial, select ""I"" and press the dial to activate Inclusion process. Now the character ""I"" starts flashing.

STEP 2: On the 3rd party device, select Inclusion for adding a device into SRT321's network.

After successful inclusion SRT321 displayed ""IP"" other wise displayed ""IF"" (Inclusion fail).

Note: Once the character starts flashing the installer has 60 seconds to activate the 3rd party device.

After successful Inclusion set DIL switch 1 to 'OFF' position to operate SRT321 in normal operation.

If the inclusion process fails more than once, the 3rd party device may be already included in another network. So first exclude and then include the device.
Factory Reset
Please use this procedure only when the primary controller is missing or otherwise inoperable.

To reset the thermostat Set DIL switch 1 on the back of the unit to 'ON' position, scroll through the function menu by rotating the dial, select ""P"" and press the dial twice on the target device to execute reset.

Note: After successful operation device displayed ""PP"".

It will put the device in factory default, that include setting all the configuration, Association to factory default and removing the device from Z-Wave network.
Learn Mode (adding another controller)
STEP 1: On the another Z-Wave controller, select Include for adding SRT321 to the network.

STEP 2: On the SRT321, Set DIL switch 1 on the back of the unit to 'ON' position, scroll through the function menu by rotating the dial, select ""L"" and press the dial to start Learn process. Now the character ""L"" starts flashing.

After successful operation SRT321 displayed ""LP"" other wise displayed ""LF"" (Learn fail).

Note: Once the character starts flashing the installer has 20 seconds to activate the 3rd party controller unit (2 seconds classic inclusion, than after 3 retries for NWI inclusion).

After successful Learn set DIL switch 1 to 'OFF' position to operate SRT321 in normal operation.

If the Learn process has failed more than once, the SRT321 may be already included in another network. So first exclude and then include the SRT321.
Device Wake-Up
SRT321 will wake-up regularly and announce the wakeup state by sending Wakeup Notification to the configured node ID if Wakeup Interval and valid node ID is set.

To forcefully wake up the device to send Wakeup notification do the following steps: Set DIL switch 1 on the back of the unit to 'ON' position, and than back to the 'OFF' position.

Note: It is possible to set the node ID to 255 to send wakeup notifications as broadcast. In this mode device takes more time to go to sleep and drains battery faster, but can notify all it's direct neighbors about a wakeup.

 

Opiniones

Escribe tu opinión

Secure SRT321 Termostato de pared con pantalla LCD Z-Wave Plus GEN5

Secure SRT321 Termostato de pared con pantalla LCD Z-Wave Plus GEN5

El termostato de pared Secure SRT321, alimentado a pilas, permite usar una rueda grande en el dispositivo para predeterminar la temperatura deseada  en la habitación.

Accesorios, complementos y/o alternativas

30 otros productos de la misma categoría:

Los clientes que compraron este producto también han comprado...