Nombre: Micromodule Energy Meter, Z-Wave
Fabricante:Zipato
Identificador:ph-pab01
Número de Certificación Z-Wave:ZC10-17065646
Plataforma Hardware:SD3502
FLiRS:NO
Tipo de Role:Always On Slave
Descripción Corta:Zipato Energy Meter monitors total electricity consumption of connected appliances and reports it to Zipato or any other Z-Wave enabled controller in real time.
Descripción:This product can be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. Zipato Energy Meter monitors total electricity consumption of connected appliances and reports it to Zipato or any other Z-Wave enabled controller in real time. Small and compact size allows easy installation in majority of electricity distribution boxes. It supports two loads upto 6000W each (@ 120V).
Descargue el manual desde aquí.
Grupo
Max Nodos
Descripción
1
1
Lifeline
For group 1, the Micromodule will report (1) The sum of instant Power Consumption (Watt) read from CT1 and CT2 (2) The sum of accumulated Power Consumption (KWh) read from CT1 and CT2.
2
1
For group 2, the Micromodule will report (1) Instant Power Consumption (Watt) read from CT1 (2) Accumulated Power Consumption (KWh) read from CT1.
3
1
For group 3, the Micromodule will report (1) Instant Power Consumption (Watt) read from CT2 (2) Accumulated Power Consumption (KWh) read from CT2.
Número
Tamaño (Bytes)
Valor por Defecto
Nombre
Descripción
1
2
720
Watt Meter Report Period
If the setting is configured for 1hour (set value =720), Micromodule will report its instant power consumption every 1 hour to the node of correspond Group. The maximum interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr).
2
2
720
KWH Meter Report Period
If the setting is configured for 1hour (set value =720), the PAB01 will report its Accumulated Power Consumption (KW/h) every 1 hour to the node of correspond Group. The maximum interval to report its Accumulated Power Consumption (KW/h) is 45 hours (5s*32767/3600=45hr).
3
1
1
Slected End Point
If Controller not using Multi_Channel command class to access the endpoint of Micromodule, you may configure the endpoint value to react the Basic Command Class, Binary Switch Command Class or Meter Command Class V3.
1. SELECTED ENDPOINT 1: Report the Meter Value as CT1+CT2. Defauly selected endpoint is 1.
2. SELECTED ENDPOINT 2: Report the Meter Value of CT1.
3. SELECTED ENDPOINT 3: Report the Meter Value of CT2.
4
2
750
Threshold of Current for Load Caution
This is a warning when the current of load over the preset threshold value, If the setting value is 750, when the load wattage of CT1 or CT2 over 7.5A, Micromodule will send current Meter Report command to the node of correspond Group.
5
2
10000
Threshold of KWH for Load Caution
This is a warning when the KWh of load over the preset threshold value, If the setting value is 10000, when the Accumulated Power Consumption of CT1 or CT2 over this value, Micromodule will send KWh Meter Report command to the node of correspond Group, minum value is 1KWh and default value is 10000 kWh.
Association Group Info
COMMAND_CLASS_ASSOCIATION_GRP_INFO
Association V2
COMMAND_CLASS_ASSOCIATION_V2
Configuration
COMMAND_CLASS_CONFIGURATION
CRC16 Encapsulation
COMMAND_CLASS_CRC_16_ENCAP
Device Reset Locally
COMMAND_CLASS_DEVICE_RESET_LOCALLY
Firmware Update Meta-Data V2
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
Manufacturer Specific V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
Meter V3
COMMAND_CLASS_METER_V3
Powerlevel
COMMAND_CLASS_POWERLEVEL
Version V2
COMMAND_CLASS_VERSION_V2
Z-Wave Plus Info V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
Factory Reset
Use this procedure only in the event that the network primary controller is missing or otherwise inoperable.
Pressing On/Off (Include) button three times within 2 seconds will enter inclusion mode.
Within 1 second, press and hold On/Off (Include) button again for 5 seconds until LED is off.
IDs are excluded.
Inclusion
Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer.
Pressing On/Off (Include) button three times within 2 seconds will enter inclusion mode.
Exclusion
Put your Z-Wave controller into exclusion mode by following the instructions provided by the controller manufacturer.
Pressing On/Off (Include) button three times within 2 seconds will enter exclusion mode.
Node ID has been excluded.
Color
If the product is only available in one color, pick the color from the list.
Switch Load Capacity Current
The amount of switch load energy the product is rated for in Amps
Electric Load Type
Select the electric load type(s) supported by the device.
Firmware Updatable
Indicates whether the firmware can be updated and whether it is done by the consumer or a technician.
Supported Meter Type
Indicate which type of metering is supported by the device.