Technical characteristics

Technology Z-Wave Plus

More info

Fibaro CO sensor protects you from invisible dangers

Fibaro's CO sensor is an ultra-light, compact, battery-powered Z-Wave carbon monoxide detector designed to be placed on a wall. Its high sensitivity makes it perfect for detecting the presence of carbon monoxide (CO) gas at an early stage in order to avoid carbon monoxide poisoning. The alarm is acoustically signaled with a siren integrated in the CO sensor itself, LED indicator and a Z-Wave message to the home automation controller. In addition, the device is equipped with a temperature sensor.

BSI certificate


The Fibaro CO sensor has the BSI Kitemark certificate with the license, recognized worldwide as a sign of quality and safety. Each sensor with BSI Kitemark symbole is subject to continuous monitoring, which covers the testing of routine products and the evaluation of the manufacturing quality control process.

Simplicity saves lives
Simple and easy-to-understand notifications allow anyone to evaluate the immediate threat.

- healthy (green): Carbon monoxide was not detected or its concentration is very low, it can relax.

- Moderate (orange): The concentration of CO can affect how you feel, be sure to ventilate the room, check the ventilation and find the source.

- CO detector (red): The level of CO is high enough to be a threat to life; follow the rules of the critical levels of CO concentration.

Extended Z-Wave info

Name: FIBARO CO Sensor
Manufacturer:FIBARO
Identifier:FGCD-001
Z-Wave Certification Number:ZC10-18076178
Hardware Plattform:ZM5101
FLiRS:NO
Role Type:Reporting Sleeping Slave
Short Description:FIBARO CO Sensor is a compact, wall-mounted, battery-powered carbon monoxide detector.
Description:FIBARO CO Sensor is an ultra-light, compact, battery-powered carbon monoxide detector, designed to be placed on a wall. Its high sensitivity allows to detect the presence of the carbon monoxide (CO) gas at the early stage in order to prevent carbon monoxide poisoning. Alarm is signalled with a built-in siren, blinking LED indicator and by sending commands to Z-Wave network devices. Additionally, the device is equipped with a temperature sensor.

Manual download HERE.

Group
Max Nodes
Description
1
1
“Lifeline” reports the device status and allows for assigning single device only (main controller by default).
2
5
“CO Alarm” is assigned to the device status - devices in this group will be switched on/off when CO Alarm status changes.
3
5
“CO Alarm” is assigned to the device status - devices in this group will receive notification when CO Alarm status changes. Useful for devices that can trigger alarms.
4
5
“CO Level” is assigned to measured CO level - devices in this group will be switched on/off after exceeding the level of CO concentration specified in parameter 14.
5
5
“Tamper Alarm” is assigned to the tamper - sends tamper alarm and cancellation frames to the associated devices.
6
5
“CO Alarm BC” is assigned to the device status - devices in this group will be switched on/off when CO Alarm status changes. Provides backward compatibility with controllers not supporting Z-Wave+ protocol.
7
5
“Tamper Alarm BC” is assigned to the tamper - sends tamper alarm and alarm cancellation frames to the associated devices. Provides backward compatibility with controllers not supporting Z-Wave+ protocol.
Number
Size (Bytes)
Default Value
Name
Description
10
1
3
Commands sent to 2nd association group (CO Alarm)
This parameter defines commands sent to devices associated in 2nd association group (CO Alarm). Values of specified commands may be set in parameters 11 and 12.
11
2
255
Value of BASIC ON command sent to 2nd association group
This parameter defines the value of BASIC ON command sent to devices in 2nd association group after the CO Alarm activation. 1-99 - forcing level of associated devices 255 - setting associated devices to the last remembered state or turning them on
12
2
0
Value of BASIC OFF command sent to 2nd association group
This parameter defines the value of BASIC OFF command sent to devices in 2nd association group after the CO Alarm cancellation. 1-99 - forcing level of associated devices 255 - setting associated devices to the last remembered state or turning them on
13
1
3
Commands sent to 4th association group (CO Level)
This parameter defines commands sent to devices associated in 4th association group (CO Level). Values of specified commands may be set in parameters 16 and 19.
14
2
40
CO level required for sending BASIC ON command to 4th association group
This parameter defines the minimum level of CO concentration which exceeding will result in starting the timer set in parameter 15.
15
2
0
Time required for sending BASIC ON command to 4th association group
This parameter defines the time during which the level of CO concentration should remain above the value set in parameter 14 to send the BASIC ON command to 4th association group.
16
2
255
Value of BASIC ON command sent to 4th association group
This parameter defines the value of BASIC ON command sent to devices in 4th association group after exceeding the CO level set in parameter 14 through the time set in parameter 15. 1-99 - forcing level of associated devices 255 - setting associated devices to the last remembered state or turning them on
17
2
25
CO Level required for sending BASIC OFF command to 4th association group
This parameter defines the maximum level of CO concentration below which falling will result in starting the timer set in parameter 18.
18
2
0
Time required for sending BASIC OFF command to 4th association group
This parameter defines the time during which the level of CO concentration should remain below the value set in parameter 17 to send the BASIC OFF command to 4th association group.
19
2
0
Value of BASIC OFF command sent to 4th association group
This parameter defines the value of BASIC OFF command sent to devices in 4th association group after falling below the CO level set in parameter 17 through the time set in parameter 18. 1-99 - forcing level of associated devices 255 - setting associated devices to the last remembered state or turning them on
2
1
0
Z-Wave notifications
This parameter allows to set the actions which result in sending notifications to the Z-Wave network controller.
20
2
0
Temperature reporting time interval
Time interval (in seconds) between consecutive reports of temperature (done by built-in temperature sensor). Short time interval means more frequent communication, which results in shortened battery life.
21
1
2
Temperature reporting hysteresis
This parameter defines a minimum change in temperature resulting in a report being sent to the main Z-Wave controller.
22
1
55
Threshold of exceeding the temperature
This parameter defines the temperature level, which exceeding will result in sending actions set in parameters 2, 3 and 4.
23
1
1
CO meter activation
This parameter activates reporting the value of CO concentration level to the main Z-Wave controller.
25
1
2
CO level reporting hysteresis
This parameter defines a minimum change in CO concentration level which results in sending a new value to the main Z-Wave controller.
26
2
30
Threshold of CO meter activation
This parameter defines the CO concentration level, which exceeding will result in sending a new value to the main Z-Wave controller, according to parameter 25 settings. Adjusting the value allows to get the accurate data in case of danger and helps to save the battery in normal conditions.
3
1
0
LED diode indications
This parameter allows to set the actions which result in LED diode indications. This parameter does not apply to the most important actions, such as CO Alarm, Malfunction Alarm and Low Battery Alarm.
4
1
0
Acoustic signals
This parameter allows to set the actions which result in acoustic signals. This parameter does not apply to the most important actions, such as CO Alarm, Malfunction Alarm and Low Battery Alarm.
7
1
63
Associations in Z-Wave network security mode
Parameter defines how commands are sent in specified association groups: as secure or non-secure. Parameter is active only in Z-Wave network security mode. It does not apply to 1st “Lifeline” association group. Parameter 7 values may be combined, e.g. 1+2=3 means that 2nd & 3rd group are sent as secure.
Basic
COMMAND_CLASS_BASIC
Application Status
COMMAND_CLASS_APPLICATION_STATUS
Association Group Information V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3
Association V2
COMMAND_CLASS_ASSOCIATION_V2
Battery
COMMAND_CLASS_BATTERY
Configuration
COMMAND_CLASS_CONFIGURATION
CRC16 Encapsulation
COMMAND_CLASS_CRC_16_ENCAP
Device Reset Locally
COMMAND_CLASS_DEVICE_RESET_LOCALLY
Firmware Update Meta-Data V3
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V3
Manufacturer Specific V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
Multi-Channel Association V3
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
Notification V5
COMMAND_CLASS_NOTIFICATION_V5
Powerlevel
COMMAND_CLASS_POWERLEVEL
Security S0
COMMAND_CLASS_SECURITY
Sensor Alarm
COMMAND_CLASS_SENSOR_ALARM
Sensor Multilevel V10
COMMAND_CLASS_SENSOR_MULTILEVEL_V10
Version V2
COMMAND_CLASS_VERSION_V2
Wake Up V2
COMMAND_CLASS_WAKE_UP_V2
Z-Wave Plus Info V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
Inclusion
1) Place the device within direct range of the Z-Wave controller.

2) Set the main Z-Wave controller in (security/non-security) adding mode (see the controller’s manual).

3) Quickly, triple click the button located on the casing.

4) Wait for the device to be added into the system.

5) Successful adding will be confirmed by the Z-Wave controller’s message.

Exclusion
1) Place the device within direct range of the Z-Wave controller.

2) Set the main Z-Wave controller in remove mode (see the controller’s manual).

3) Quickly, triple click the button located on the casing.

4) Wait for the removing process to end.

5) Successful removing will be confirmed by the Z-Wave controller’s message.

Factory Reset
1) Press and hold the button.

2) Release the button when LED indicator glows white.

3) Click the button when LED indicator glows yellow.

4) After few seconds the device will be reset (confirmed by red LED indicator).



Resetting the device is not the recommended way of removing the device from the Z-Wave network. use the reset procedure only if the primary controller is missing or inoperable.

Device Wake-Up
The CO Sensor needs to be woken up to receive information about the new configuration from the Z-Wave controller, like parameters and associations. To wake up the sensor manually click the button located on the casing.
Battery Quantity
Enter the number of batteries of the designated type that the product uses.
Battery Type
Enter the type (e.g. AA, CR2032, AAA) of the battery/batteries that the product uses.
Color
If the product is only available in one color, pick the color from the list.
Firmware Updatable
Indicates whether the firmware can be updated and whether it is done by the consumer or a technician.
Sensors
Sensor types supported by the product.
Supported Notification Types
Select the Notification Types that the product handles (controllers), or sends (slaves).

 

Reviews

Write a review

FIBARO CO SENSOR - Z-Wave Plus carbon monoxide detector

FIBARO CO SENSOR - Z-Wave Plus carbon monoxide detector

is an ultra-light, compact and battery-powered Z-Wave carbon monoxide detector, designed to be placed on the wall.

14 other products in the same category:

Customers who bought this product also bought: