Technical characteristics

Technology Z-Wave Plus

Extended Z-Wave info

Name: FIBARO Button
Manufacturer:FIBARO
Identifier:FGPB-101
Z-Wave Certification Number:ZC10-16105252
Hardware Plattform:ZM5101
FLiRS:NO
Role Type:Portable Slave
Short Description:FIBARO Button is a compact, battery-powered, Z-Wave scene controller.
Description:FIBARO Button is a compact, battery-powered, Z-Wave Plus compatible device. It allows you to control devices through the Z-Wave network and run various scenes defined in FIBARO System. Different actions may be triggered with one to five clicks or by holding the button down. In Panic Button mode, each press of the button results in triggering the Fibaro Alarm. With its small design and wireless communication, the FIBARO Button can be conveniently mounted on any surface and in any position or location at home, e.g. beside the bed or under the desk.

Manual download HERE.

Group
Max Nodes
Description
1
1
Lifeline reports the device status and allows for assigning single device only (main controller by default).
2
5
On/Off is assigned to clicking the button and is used to turn on/off associated devices.
3
5
Dimmer is assigned to holding the button and is used to change level of associated devices.
4
5
Alarm is assigned to clicking and/or holding the button (triggers are defined in parameter 30) and is used to send alarm frames to associated devices.
Number
Size (Bytes)
Default Value
Name
Description
1
1
127
Scenes sent to the controller
This parameter determines which actions result in sending scene IDs and attributes assigned to them. 1 - Key Pressed 1 time 2 - Key Pressed 2 times 4 - Key Pressed 3 times 8 - Key Pressed 4 times 16 - Key Pressed 5 times 32 - Key Held Down 64 - Key Released NOTE Values of parameter 1 may be combined, e.g. 1+2=3 means that scenes will be sent after pressing the button once or twice.
10
1
3
Key Pressed 1 time – command sent to 2nd association group
This parameter defines commands sent to devices associated in 2nd association group after a single click. 0 - no action 1 - SWITCH ON 2 - SWITCH OFF 3 - SWITCH ON/OFF – alternately
11
2
255
Key Pressed 1 time – value of SWITCH ON command sent to 2nd association group
This parameter defines value of SWITCH ON command sent to devices in 2nd association group after a single click. 1-255- sent value NOTE Setting parameters 11, 13, 15, 21, 23 and 25 to appropriate value will result in: 1-99 - forcing level of associated devices 255 - setting associated devices to the last remembered state or turning them on
12
1
1
Key Pressed 2 times – command sent to 2nd association group
This parameter defines commands sent to devices associated in 2nd association group after a double click. 0- no action 1- SWITCH ON 2- SWITCH OFF 3- SWITCH ON/OFF – alternately
13
2
99
Key Pressed 2 times – value of SWITCH ON command sent to 2nd association group
This parameter defines value of SWITCH ON command sent to devices in 2nd association group after a double click. 1-255 - sent value
14
1
0
Key Pressed 3 times – command sent to 2nd association group
This parameter defines commands sent to devices associated in 2nd association group after a triple click. 0- no action 1- SWITCH ON 2- SWITCH OFF 3- SWITCH ON/OFF – alternately
15
2
255
Key Pressed 3 times – value of SWITCH ON command sent to 2nd association group
This parameter defines value of SWITCH ON command sent to devices in 2nd association group after a triple click. 1-255 - sent value
20
1
3
Key Pressed 1 time – command sent to 3rd association group
This parameter defines commands sent to devices associated in 3rd association group after a single click. 0- no action 1- SWITCH ON 2- SWITCH OFF 3- SWITCH ON/OFF – alternately
21
2
255
Key Pressed 1 time – value of SWITCH ON command sent to 3rd association group
This parameter defines value of SWITCH ON command sent to devices in 3rd association group after a single click. 1-255 - sent value
22
1
1
Key Pressed 2 times – command sent to 3rd association group
This parameter defines commands sent to devices associated in 3rd association group after a double click. 0 - no action 1- SWITCH ON 2- SWITCH OFF 3- SWITCH ON/OFF – alternately
23
2
99
Key Pressed 2 times – value of SWITCH ON command sent to 3rd association group
This parameter defines value of SWITCH ON command sent to devices in 3rd association group after a double click. 1-255 - sent value
24
1
0
Key Pressed 3 times – command sent to 3rd association group
This parameter defines commands sent to devices associated in 3rd association group after a triple click. 0 - no action 1- SWITCH ON 2- SWITCH OFF 3 - SWITCH ON/OFF – alternately
25
2
255
Key Pressed 3 times – value of SWITCH ON command sent to 3rd association group
This parameter defines value of SWITCH ON command sent to devices in 3rd association group after a triple click. 1-255 - sent value
29
1
3
Key Held Down – command sent to 3rd association group
This parameter defines commands sent to devices associated in 3rd association group after holding the button down. 0- no action 1- START LEVEL CHANGE UP (brightening) 2- START LEVEL CHANGE DOWN (dimming) 3- START LEVEL CHANGE UP/DOWN (brightening/dimming) – alternately
3
1
7
Associations in Z-Wave network security mode
This parameter defines how commands are sent in specified association groups: as secure or non-secure. Parameter is active only in Z-Wave network security mode. It does not apply to 1st „Lifeline” group. 1 - 2nd group sent as secure 2 - 3rd group sent as secure 4 - 4th group sent as secure NOTE Values of parameter 3 may be combined, e.g. 1+2=3 means that 2nd & 3rd group are sent as secure.
30
1
127
Alarm frame triggers
Parameter determines which actions result in sending alarm frames to 4th association group. 1 - Key Pressed 1 time 2 - Key Pressed 2 times 4 - Key Pressed 3 times 8 - Key Pressed 4 times 16 - Key Pressed 5 times 32 - Key Held Down 64 - Key Released NOTE Values of parameter 30 may be combined, e.g. 1+2=3 means that alarm frames will be sent after pressing the button once or twice.
Basic
COMMAND_CLASS_BASIC
Switch Multilevel V3
COMMAND_CLASS_SWITCH_MULTILEVEL_V3
Association Group Info
COMMAND_CLASS_ASSOCIATION_GRP_INFO
Association V2
COMMAND_CLASS_ASSOCIATION_V2
Battery
COMMAND_CLASS_BATTERY
Central Scene V3
COMMAND_CLASS_CENTRAL_SCENE_V3
Configuration
COMMAND_CLASS_CONFIGURATION
CRC16 Encapsulation
COMMAND_CLASS_CRC_16_ENCAP
Device Reset Locally
COMMAND_CLASS_DEVICE_RESET_LOCALLY
Firmware Update Meta-Data V3
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V3
Manufacturer Specific V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
Multi-Channel Association V3
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
Notification V5
COMMAND_CLASS_NOTIFICATION_V5
Powerlevel
COMMAND_CLASS_POWERLEVEL
Security S0
COMMAND_CLASS_SECURITY
Sensor Alarm
COMMAND_CLASS_SENSOR_ALARM
Version V2
COMMAND_CLASS_VERSION_V2
Wake Up V2
COMMAND_CLASS_WAKE_UP_V2
Z-Wave Plus Info V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
Device Wake-Up
The Button needs to be woken up to receive information about the new configuration from the controller, like parameters and associations.

1) Click the Button 4 times to wake it up

Inclusion
1) Place the Button within the direct range of your Z-Wave controller.

2) Set the main controller in (security/non-security) add mode (see the controller’s manual).

3) Click the Button at least six times.

4) Wait for the adding process to end.

5) Successful adding will be confirmed by the Z-Wave controller’s message.

Exclusion
1) Place the Button within the direct range of your Z-Wave controller.

2) Set the main controller in remove mode (see the controller’s manual).

3) Click the Button at least six times.

4) Wait for the removing process to end.

5) Successful removing will be confirmed by the Z-Wave controller’s message.

Factory Reset
Reset procedure allows to restore the device back to its factory settings, which means all information about the Z-Wave controller and user configuration will be deleted. In order to reset the device:

1) Click the Button exactly five times.

2) Press and hold the Button for at least 5 seconds.

Please use this procedure only when the network primary controller is missing or otherwise inoperable
Battery Quantity
Enter the number of batteries of the designated type that the product uses.
Battery Type
Enter the type (e.g. AA, CR2032, AAA) of the battery/batteries that the product uses.
Firmware Updatable
Indicates whether the firmware can be updated and whether it is done by the consumer or a technician.
Z-Wave Scene Type
Indicates which of the two types of Z-Wave scene command classes are supported. Scenes or Central Scene

 

Reviews

Grade 
09/9/2018

Fibaro botón

Se atasca mucho, tengo dos y le pasa a los dos.