Philio PAN04-1B Z-Wave Plus 2x1,5 Kw - Micromódulo interruptor de 2 relés y control de consumo View larger

Philio PAN04-1B Z-Wave Plus 2x1,5 Kw - Micromódulo interruptor de 2 relés y control de consumo

PHIEPAN04-1B

New

Out of stock

49,00 €

Technical characteristics

Technology Z-Wave Plus
Characteristic Consumption Measurement

Extended Z-Wave info

Name: Micro Module Switch Double w.meter
Manufacturer:Zipato
Identifier:ph-pan04.eu
Z-Wave Certification Number:ZC10-17065647
Hardware Plattform:SD3502
FLiRS:NO
Role Type:Always On Slave
Short Description:Micromodule Switch Double is a transceiver which is a Z-Wave Plus enabled device and is fully compatible with any Z-Wave enabled etwork.
Description:This product can be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. Micromodule Switch Double is a transceiver which is a Z-Wave Plus enabled device and is fully compatible with any Z-Wave enabled network. Mini size design allow the module to be easily hidden into the wall box which is good for the house decoration. There are many kinds of application for using the module to switch AC power ON and OFF, one of which is the light control. The new smart relay calibration technology can reduce the inrush current caused by the load and let the module work perfectly with many kinds of light like incandescent, fluorescent and LED light. This Micromodule is able to detect Instant power wattage and overload wattage (current 7.5A) of connected light or appliances. When detecting overload state, the switch will be disabled and its ON/OFF button will be locked during which LED will flash repeatedly. Unplugging and reconnecting the Module will reset its overload condition to normal status.

Manual download HERE.

Group
Max Nodes
Description
1
1
Lifeline Micromodule can be set to send reports in order to control associated Z-Wave devices. It supports 3 association groups which every group has one node support. Group1~Group3 support SWITCH_BINARY_REPORT, METER_REPORT_COMMAND_V3 For group 1, Micromodule will report (1) ON/OFF status of Relay1 and Relay2 (2) Instant Power Consumption (Watt) of Relay1 and Relay2 (3) Accumulated Power Consumption (KWh) of Relay1 and Relay2 to Z-Wave Controller.
2
1
For group 2, Micromodule will report (1) ON/OFF status of Relay1 (2) Instant Power Consumption (Watt) of Relay1 (3) Accumulated Power Consumption (KWh) of Relay1 to Z-Wave Controller.
3
1
For group 3, Micromodule will report (1) ON/OFF status of Relay2 (2) Instant Power Consumption (Watt) of Relay2 (3) Accumulated Power Consumption (KWh) of Relay2 to Z-Wave Controller.
Number
Size (Bytes)
Default Value
Name
Description
1
2
720
Watt Meter Report Period
If the setting is configured for 1hour (set value =720), Micromodule will report its instant power consumption every 1 hour to the node of correspond Group. The maximum interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr).
10
1
1
Existence of Endpoint3
Multi-Channel Command is a good way to control relay1 and relay2 of Switch individually. The endpoint3 of Micromodule is related to both relay1 and relay2. In some condition it becomes redundant in Multi-Channel Command Class. When the Existence of Endpoint3 is set as 2, the endpoint3 will be disabled. The default value is 1. Endpoint1 and Endpoint2 are fixed, only Endpoint3 is dynamic.
2
2
6
KWH Meter Report Period
If the setting is configured for 1hour (set value =6), Micromodule will report its Accumulated Power Consumption (KW/h) every 1 hour to the node of correspond Group. The maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 days (10min*32767/1440=227.55 days).
3
1
1
Slected End Point
If Micromodule is not using Multi_Channel command class to access the relay of Switch, you may configure the select value to react the Basic Command Class, Binary Switch Command Class or Meter Command Class V3. 1.SELECTED RELAY1: Only relay1 can be controlled and report. 2.SELECTED RELAY2: Only relay2 can be controlled and report. 3.SELECTED RELAY1 AND RELAY2: DEFAULT SELECT IS 3 Both relay1 and relay2 can be controlled and report.
4
1
1
Edge or Pulse mode or Edge-Toggle mode
Manual switch S1 and S2 can set to Edge mode or Pulse mode or Edge-Toggle mode, default value is Edge mode. 1.EDGE MODE : This mode is suitable for the bi stable wall switch that has indicator point on the Micromodule, and the same position correspond to same state of relay1 and relay2. if the Switch’s relay changes the state because of receiving Z-Wave RF command, it may need two switchings (switch on to off or switch off to on) to let relay back to the corresponding state. 2.PULSE MODE : This mode is suitable for the toggle type wall switch to swap the state of Relay1 or Relay2. 3. EDGE-TOGGLE MODE : This mode is suitable for the normal bi-stable switch, every state change of the wall switch will also swap the state of Relay1 or Relay2.
5
2
750
Threshold of Current for Load Caution
This is a warning when the wattage of load over the preset threshold value, If the setting value is 750, when the load wattage of Relay1 or Relay2 over this value, Micromodule will send Watt Meter Report command to the node of correspond Group, the Range of the setting value is from 10 to 750, and the default value is 750.
6
2
10000
Threshold of KWH for Load Caution
This is a warning when the KWh of load exceeds preset threshold value, If the setting value is 1000, when the Accumulated Power Consumption of Relay1 or Relay2 exceeds this value, Micromodule will send KWh Meter Report command to the node of corresponding Group, the Range of the setting value is from 10 to 1000, and the default value is 750.
7
1
1
Restore switch state mode
Whenever the AC power return from lost, Micromodule will restore the switch state which could be SWITCH OFF, LAST SWITCH STATE, SWITCH ON. The default setting is LAST SWITCH STATE.
8
2
0
Auto off timer
Whenever Micromodule switches to on, the auto off timer begin to count down. After the timer decrease to zero, it will switch off automatically. However if Auto off timer is set as 0, the auto off function will be disabled. The default setting is 0.
9
1
0
RF Switch off command mode
Whenever a switch off command, BASIC_SET , BINARY_SWITCH_SET, SWITCH_ALL_OFF, is received, it could be interpreted as 4 kinds of commands. 1.SWITCH OFF : It switches to OFF state. The default setting is Switch Off. 2.IGNORE : The switch off command will be ignored. 3.SWITCH TOGGLE : It switches to the inverse of current state. 4.SWITCH ON : It switches to ON state.
Alarm
COMMAND_CLASS_ALARM
Association Group Info
COMMAND_CLASS_ASSOCIATION_GRP_INFO
Association V2
COMMAND_CLASS_ASSOCIATION_V2
Basic
COMMAND_CLASS_BASIC
Configuration
COMMAND_CLASS_CONFIGURATION
Device Reset Locally
COMMAND_CLASS_DEVICE_RESET_LOCALLY
Firmware Update Meta-Data V2
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
Manufacturer Specific V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
Meter V3
COMMAND_CLASS_METER_V3
Multi-Channel V3
COMMAND_CLASS_MULTI_CHANNEL_V3
Powerlevel
COMMAND_CLASS_POWERLEVEL
Protection V2
COMMAND_CLASS_PROTECTION_V2
Scene Activation
COMMAND_CLASS_SCENE_ACTIVATION
Scene Actuator Conf
COMMAND_CLASS_SCENE_ACTUATOR_CONF
Switch All
COMMAND_CLASS_SWITCH_ALL
Switch Binary
COMMAND_CLASS_SWITCH_BINARY
Version V2
COMMAND_CLASS_VERSION_V2
Z-Wave Plus Info V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
Factory Reset
Use this procedure only in the event that the network primary controller is lost or otherwise inoperable.

Pressing INCLUDE_BUTTON three times within 2 seconds will enter inclusion mode.

Within 1 second, press On/Off button again for 5 seconds until LED is off.

IDs are excluded.
Exclusion
Have Z-Wave Controller entered exclusion mode by following the instructions provided by the controller manufacturer.

Pressing INCLUDE_BUTTON three times within 2 seconds will enter exclusion mode.

Node ID has been excluded.
Inclusion
Have Z-Wave Controller entered inclusion mode by following the instructions provided by the controller manufacturer.

Pressing INCLUDE_BUTTON threetimes within 2 seconds will enter inclusion mode.
Firmware Updatable
Indicates whether the firmware can be updated and whether it is done by the consumer or a technician.
Switch Load Capacity Current
The amount of switch load energy the product is rated for in Amps
Supported Meter Type
Indicate which type of metering is supported by the device.
Color
If the product is only available in one color, pick the color from the list.
Electric Load Type
Select the electric load type(s) supported by the device.
Switch Type
Describes the type of operator for a switch.

 