Number
Size (Bytes)
Default Value
Name
Description
10
1
12
Auto Report Battery Time
The interval time for
auto report the battery
level. 0 means turn off
auto report battery.
The default value
is 12. The tick time
can setting by the
configuration No.20.
11
1
12
Auto Report Door/ Window State Time
The interval time for
auto report the door/
window state. 0 means
turn off auto report
door/window state. The
default value is 12. The
tick time can setting
by the configuration
No.20.
12
1
12
Auto Report Illumination Time
The interval time
for auto report the
illumination. 0 means
turn off auto report
illumination. The
default value is 12. The
tick time can setting
by the configuration
No.20.
13
1
12
Auto Report Temperature Time
The interval time
for auto report the
temperature. 0 means
turn off auto report
illumination. The
default value is 12. The
tick time can setting
by the configuration
No.20.
2
1
-1
Basic Set Level
Setting the BASIC
command value to
turn on the light.
The 0xFF(-1) means
turn on the light. For
dimmer equipment 1
to 100 means the light
strength.
20
1
30
Auto Report Tick Interval
The interval time
for auto report each
tick. Setting this
configuration will
effect configuration
No.10, No.11, No.12
and No.13. Caution:
Setting to 0 means
turn off
all auto report function.
21
1
1
Temperature Differential Report
The temperature
differential to report.
0 means turn off this
function. The unit is
Fahrenheit. Enable this
function the device will
detect every minutes.
And when the
temperature is over 140
degree Fahrenheit, it
will continue report.
Enable this
functionality will cause
some issue please
see the detail in the
“Temperature Report”
section.
22
1
0
Illumination Differential Report
The illumination
differential to report.
0 means turn off this
function. The unit is
percentage. Enable this
function the device will
detect every minutes.
Enable this
functionality will cause
some issue please
see the detail in the
“Illumination Report”
section.
3
1
80
PIR Sensitivity
PIR sensitivity settings.
0 means disable the
PIR motion.
1 means the lowest
sensitivity,
99 means the highest
sensitivity.
High sensitivity means
can detected long
distance, but if there is
more noise signal
in the environment, it
will re-trigger too
frequency.
4
1
99
Light Threshold
Setting the illumination
threshold to turn
on the light. When
the event triggered
and the environment
illumination lower
then the threshold, the
device will turn
on the light.
0 means turn off
illumination detected
function. And never
turn on the light.
1 means darkest.
99 means brightest.
100 means turn off
illumination detected
function. And always
turn on the light.
Notice: In none test
mode, only the
value in 1 to 99 will
enable the
illumination detected
function and
update the illumination
value.
5
1
0
Operation Mode
Operation mode. Using
bit to control.
6
1
4
Multi-Sensor Function Switch
Multisensor function
switch. Using bit
to control.
7
1
4
Customer Function
Customer function
switch, using bit control.
8
1
3
PIR Re- Detect Interval Time
In the normal mode,
after the PIR motion
detected, setting
the re-detect time.
8 seconds per tick,
default tick is 3 (24
seconds). Setting
the suitable value to
prevent received the
trigger signal too
frequently. Also can
save the battery energy.
9
1
4
Turn Off Light Time
After turn on the
lighting, setting the
delay time to turn
off the lighting when
the PIR motion is not
detected. 8 seconds per
tick, default tick is 4 (32
seconds).
0 means never send
turn off light command.